750-337/025-000 Fieldbus Coupler CANopen MCS ext. Temperature

Back| Overview|Product 27 of 34 in this category Prev|Next
750-337/025-000 Fieldbus Coupler CANopen MCS ext. Temperature
For a larger view click on the thumbnail
750-337/025-000 Fieldbus Coupler CANopen MCS ext. Temperature
750-337/025-000 Fieldbus Coupler CANopen MCS ext. Temperature
Stock quantity: 0 pcs. / order item
Product no.: 750-337/025-000
GTIN/EAN: 4045454783235
MPN: 750-337/025-000
Weight: 0.180 kg
Manufacturer: WagoMore products of: Wago
For further information, please visit the homepage of this product.
270,42 €
19 % VAT incl. excl. Shipping costs
Netto:227,24 €
* Valid for shipments within Germany.
Delivery times to other countries and information how to calculate see here


Wago

  • Details
  • Data sheet
  • Features

Products description

Wago 750-337/025-000 WAGO-I/O-SYSTEM 750 Fieldbus Coupler

 

Fieldbus Coupler CANopen, MCS, digitale and analoge signals, for ext. Temperature, Baud rate: 10 kbaud-1 Mbaud, Buscoupler connection: (MSS) female connector 231-305/010-000 in scope of supply, no. of I/O modules: 64, input process image max.: 512 Byte, output process image max.: 512 Byte, no. of PDO: 32 Tx/32 Rx, no. of SDO: 2 Server SDO, no. of couplers connected to Master: 110

 

General Description

This fieldbus coupler links the WAGO-I/O SYSTEM as a slave to the CANopen fieldbus.
The module data is transmitted using PDOs and SDOs.

The bus coupler recognizes all connected I/O modules and creates a local process image on this basis.
Analog and specialty module data is sent via words and/or bytes, digital data is sent bit by bit.

The local process image is divided into two data zones containing: data received and data to be sent.
The process data can be sent via the CANopen bus to a control system for further processing.
The process output data can be sent via the CANopen bus.

The data of the analog modules is stored in the PDOs according to the order in which the modules are connected to the buscoupler.
The bits from the digital modules are sent byte by byte and also mapped in the PDOs.
If the amount of digital information exceeds 8 bits, the buscoupler automatically starts with a new byte.

All entries of the object directory can be mapped, as the user likes, in the 32 Rx PDOs and 32 Tx PDOs.

The complete input and output process image can be transmitted using SDOs.

Spacer modules can be set via software.

Note: EDS files required

Buscoupler connection:

5-pole male connector, 231 Series (MCS), female connector 231-305/ 010-000 (included)

Datenblatt: 750-337/025-000 Fieldbus Coupler CANopen MCS ext. Temperature

Product Features

Type:-
Communikation:CANopen
Back| Overview|Product 27 of 34 in this category Prev|Next